Paddock Sentry: passive network sensor¶
Sentry gives Paddock eyes inside a network: every camera, printer,
thermostat, smart fridge, PLC and building controller, what it is, and
whether it is behaving like what it is. It is a small program (standard-
library Python plus tcpdump) that runs on a Raspberry Pi, a mini-PC, a VM
or a router, and listens to a mirror (SPAN) port.
What it guarantees¶
- Listen-only. Sentry never sends a packet to, connects to, or probes a device. The only connection it may open is to your Paddock server, enforced at runtime by an egress guard and covered by tests.
- Metadata, not content. It ships flow summaries (who talked to whom, on which port, how much) and device announcements (DHCP / mDNS / SSDP). Payload bytes leave the sensor only for industrial protocols (Modbus, S7, DNP3, BACnet, EtherNet/IP, OPC-UA, ...), and only the first ~96 bytes of a few packets per flow, because identifying the protocol needs the header.
- Survives outages. If the server is unreachable it keeps a bounded on-disk outbox (default 256 MB) and catches up when the link returns.
What you get¶
| Detector | Severity | Fires when |
|---|---|---|
device_lateral_scan |
high | an IoT/OT device initiates to ≥ 16 internal hosts, or ≥ 24 ports on one host, within 15 min |
ot_internet_egress |
high | an OT device (PLC, RTU, controller) initiates a connection to a public address |
iot_crosses_segment |
medium | an IoT device initiates to another internal segment on a non-infrastructure port |
cleartext_management |
medium | someone manages a device over Telnet / FTP / TFTP / SNMP v1-2c |
behavior_drift |
medium | after a 7-day learning period, a device model starts a kind of connection none of its kind made before |
ot_it_exposure, ot_public_exposure |
high | (existing) OT not isolated from IT, or on a public address |
Plus:
- device inventory (vendor, type, model, role: IT / IoT / OT)
- CVE matching for identified device models
- the observed segmentation map, which segments really reach which (
can_reach_observededges in the graph)
Baselines are learned per device class (vendor + type + model), not per device. A second identical camera is protected the moment it appears.
1. Get a copy of the traffic¶
Pick one:
| Gear | How |
|---|---|
| UniFi | Devices → switch → Ports → port → Port Profile/Manage → Port Mirroring: mirror the uplink (or the IoT VLAN's ports) to the Sentry's port |
| Cisco IOS | monitor session 1 source interface Gi1/0/1 both · monitor session 1 destination interface Gi1/0/24 |
| Aruba / HPE | mirror-port 24 then interface 1 monitor (or a mirror session on CX) |
| MikroTik | Switch → Port settings → mirror-source / mirror-target |
| VMware vSwitch | Port group → Security → Promiscuous mode: Accept, run Sentry as a VM on that port group |
| No managed switch | an inexpensive passive network TAP inline on the uplink |
| OpenWrt / router | rotate captures into a directory (tcpdump -G 60 -w /tmp/cap/%s.pcap) and run Sentry with --spool /tmp/cap |
Mirror the uplink of the segment you care about (IoT VLAN, OT cell, guest Wi-Fi bridge) for the best coverage. For a Raspberry Pi, add a USB Ethernet adapter so one port mirrors and the other reaches the server.
2. Enable sensor ingest on the server¶
Generate one token per sensor:
The hardened profile refuses all sensor data until SENTRY_TOKENS is
set. The ingest endpoint is otdiscovery on port 8101; put it behind your
TLS reverse proxy.
3. Run Sentry¶
Docker (amd64 / arm64):
docker run -d --name paddock-sentry --restart unless-stopped \
--network host --cap-drop ALL --cap-add NET_RAW --cap-add NET_ADMIN \
--read-only --tmpfs /tmp -v paddock-sentry:/var/lib/paddock-sentry \
-e PADDOCK_SERVER=https://paddock.example:8101 \
-e PADDOCK_SENTRY_TOKEN=<token> -e PADDOCK_SITE=store-42 \
paddock-sentry run --iface eth1
Build the image from sentry/ with docker build -t paddock-sentry sentry/.
Bare metal / Raspberry Pi OS:
sudo apt install -y tcpdump python3-pip
sudo pip install ./sentry # provides `paddock-sentry`
paddock-sentry doctor --iface eth1 --server https://paddock.example:8101 --token <token>
The systemd unit at sentry/deploy/paddock-sentry.service
runs Sentry with only CAP_NET_RAW/CAP_NET_ADMIN.
Try it without hardware: replay a capture and see exactly what would be sent.
4. Check it is working¶
paddock-sentry doctorchecks tcpdump, interface, permissions, server reachability and token.GET http://<server>:8101/statsshows each sensor'slast_seen, batch count and last window (packets, flows, dropped flows).- Devices appear in the dashboard under Devices. Behaviour findings
appear under Findings with
rule_source = policyanddetector = device_lateral_scan | ....
Sizing¶
- Bandwidth to the server: one batch every 30 s. A busy 200-device office produces roughly 1–3k flows per window, about 100–300 KB per batch before compression.
- Capture: a Raspberry Pi 4 comfortably handles a ~100 Mbit/s mirror. Beyond that, use a mini-PC, or mirror only the IoT/OT VLANs.
- Memory: bounded by
--windowand the flow table cap (50k flows per window).
Server-side tuning (otdiscovery environment)¶
| Variable | Default | Meaning |
|---|---|---|
SENTRY_TOKENS |
— | accepted sensor tokens |
REQUIRE_SENTRY_TOKEN |
true (hardened) |
refuse ingest when no tokens are configured |
BEHAVIOR_WINDOW_S |
900 | look-back for scan / egress detection |
SCAN_HOSTS / SCAN_PORTS |
16 / 24 | lateral-scan thresholds |
BASELINE_LEARN_S |
604800 | learning period per device class |
BASELINE_PATH |
/var/lib/otdiscovery/baselines.json |
where learned profiles persist |
FLOW_RETENTION_S / MAX_OBSERVATIONS |
3600 / 200000 | memory bounds |